Published February 2007 | Version v1
Journal article

HPGe virtual point detector for radioactive disk sources

  • 1. Ben-Gurion University of the Negev, Beer-Sheva 84105 (Israel)

Description

Validity of the model of a virtual point detector (implying existence of a point where all interactions virtually occur) was confirmed for measurements of radioactive disk sources with HPGe detectors. The existing correlation of the count rates with the distance between the virtual plain detector and the detector face makes it possible to inter- and extrapolate calibration curves for disk radioactive sources for use at different source-detector face distances. The dependence of the distance between the virtual plane detector and the detector face on the photon energy was studied for sources of various radii

Additional details

Identifiers

DOI
10.1016/j.apradiso.2006.08.002;
PII
S0969-8043(06)00306-X;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
65
Journal Issue
2
Journal Page Range
p. 253-258
ISSN
0969-8043
CODEN
ARISEF

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
38028782
Subject category
S07: ISOTOPES AND RADIATION SOURCES;
Descriptors DEI
CALIBRATION; COUNTING RATES; EXTRAPOLATION; HIGH-PURITY GE DETECTORS; INTERPOLATION; RADIATION SOURCES
Descriptors DEC
GE SEMICONDUCTOR DETECTORS; MATHEMATICAL SOLUTIONS; MEASURING INSTRUMENTS; NUMERICAL SOLUTION; RADIATION DETECTORS; SEMICONDUCTOR DETECTORS

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.