Published May 2000 | Version v1
Book

A LOCA analysis for AHWR caused by ECCS header rupture

  • 1. Reactor Safety Div., Bhabha Atomic Research Centre, Mumbai (India)

Description

Loss of coolant accident (LOCA) analyses for the proposed 750 MWth Advanced Heavy Water Reactor (AHWR), initiated by the rupture of 8 inch NB ECCS header has been carried out. This paper narrates the description of AHWR and associated ECCS, postulated scenario with which the analyses is carried out, results, discussion and conclusion

Part of:
Eleventh annual conference of Indian Nuclear Society on power from thorium status, strategies and directions. V. 1: extended abstracts of contributed papers and programme

Additional details

Publishing Information

Publisher
Indian Nuclear Society
Imprint Place
Mumbai (India)
Imprint Title
Eleventh annual conference of Indian Nuclear Society on power from thorium status, strategies and directions. V. 1: extended abstracts of contributed papers and programme
Imprint Pagination
290 p.
Journal Page Range
p. 123-126

Conference

Title
11. annual conference of Indian Nuclear Society on power from thorium status, strategies and directions
Acronym
INSAC-2000
Dates
1-2 Jun 2000
Place
Mumbai (India)

Optional Information

Notes
3 figs.