Published February 2002
| Version v1
Journal article
Calculated and measured dose distribution in electron and X-ray irradiated water phantom
Description
The Bremsstrahlung yields produced by incident electrons on a tantalum converter have been calculated by using a Monte-Carlo computer code. The tantalum thickness as an X-ray converter was optimized for 2, 2.5, 5, 7.5, and 10 MeV electron beams. The dose distribution in scanning and conveyor direction for both 2 MeV electron and X-ray converted from 2 MeV electron beam have been calculated and compared with experimental results. The economical aspects of low energy electron conversion were discussed as well.
Additional details
Identifiers
- PII
- S0969806X01002304;
Publishing Information
- Journal Title
- Radiation Physics and Chemistry (1993)
- Journal Volume
- 63
- Journal Issue
- 2
- Journal Page Range
- p. 177-183
- ISSN
- 0969-806X
- CODEN
- RPCHDM
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- Iran, Islamic Republic of
- INIS RN
- 43042275
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S38: RADIATION CHEMISTRY, RADIOCHEMISTRY AND NUCLEAR CHEMISTRY;
- Descriptors DEI
- BREMSSTRAHLUNG; COST; ELECTROMAGNETIC RADIATION; ELECTRON EXCHANGE; IRRADIATION; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; X-RAY EQUIPMENT
- Descriptors DEC
- DOSES; ELECTROMAGNETIC RADIATION; ELECTRON TRANSFER; EQUIPMENT; RADIATIONS
Optional Information
- Copyright
- Copyright (c) 2002 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.
- Notes
- This record replaces 34055335