Published February 2002 | Version v1
Journal article

Calculated and measured dose distribution in electron and X-ray irradiated water phantom

Description

The Bremsstrahlung yields produced by incident electrons on a tantalum converter have been calculated by using a Monte-Carlo computer code. The tantalum thickness as an X-ray converter was optimized for 2, 2.5, 5, 7.5, and 10 MeV electron beams. The dose distribution in scanning and conveyor direction for both 2 MeV electron and X-ray converted from 2 MeV electron beam have been calculated and compared with experimental results. The economical aspects of low energy electron conversion were discussed as well.

Additional details

Identifiers

PII
S0969806X01002304;

Publishing Information

Journal Title
Radiation Physics and Chemistry (1993)
Journal Volume
63
Journal Issue
2
Journal Page Range
p. 177-183
ISSN
0969-806X
CODEN
RPCHDM

Optional Information

Copyright
Copyright (c) 2002 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.
Notes
This record replaces 34055335