Published August 1, 1992 | Version v1
Journal article

Vibration analysis of the photon shutter designed for the Advanced Photon Source

  • 1. Argonne National Lab., IL (United States). Advanced Photon Source, Experimental Facility Div.

Description

The photon shutter is a critical component of the beamline front end for the 7 GeV Advanced Photon Source (APS) project, now under construction at Argonne National Laboratory (ANL). The shutter is designed to close in tens of milliseconds to absorb up to 10 kW heat load (with high heat flux). Our shutter design uses innovative enhanced heat transfer tubes to withstand the high heat load. Although designed to be lightweight and compact, the very fast movement of the shutter gives rise to concern regarding vibration and dynamic sensitivity. To guarantee long-term functionality and reliability of the shutter, the dynamic behavior should be fully studied. In this paper, the natural frequency and transient dynamic analysis for the shutter during operation are presented. Through analysis of the vibration characteristics, as well as stress and deformation, several options in design were developed and compared, including selection of materials for the shutter and structural details. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A
Journal Volume
319
Journal Issue
1-3
Journal Page Range
p. 71-76.
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
7. national conference and exhibition on synchrotron radiation instrumentation (SRI-7).
Dates
28-31 Oct 1991.
Place
Baton Rouge, LA (United States).