Published May 1990 | Version v1
Journal article

Accuracy of detecting stenotic changes on coronary cineangiograms using computer image processing

  • 1. National Cardiovascular Center, Suita, Osaka (Japan)

Description

To accurately interprets stenotic changes on coronary cineangiograms, an automatic method of detecting stenotic lesion using computer image processing was developed. First, tracing of artery was performed. The vessel edges were then determined by unilateral Gaussian fitting. The stenotic change was detected on the basis of the reference diameter estimated by Hough transformation. This method was evaluated in 132 segments of 27 arteries in 18 patients. Three observers carried out visual interpretation and computer-aided interpretation. The rate of detection by visual interpretation was 6.1, 28.8 and 20.5%, and by computer-aided interpretation, 39.4, 39.4 and 45.5%. With computer-aided interpretation, the agreement between any two observers on lesions and non-lesions was 40.2% and 59.8%, respectively. Therefore, visual interpretation tended to underestimate the stenotic changes on coronary cineangiograms. We think that computer-aided interpretation increase the reliability of diagnosis on coronary cineangiograms. (author)

Additional details

Publishing Information

Journal Title
Nippon Igaku Hoshasen Gakkai Zasshi
Journal Volume
50
Journal Issue
5
Series
Nippon Igaku Hoshasen Gakkai Zasshi.
Journal Page Range
533-538
ISSN
0048-0428
CODEN
NHGZA