Published November 1982
| Version v1
Report
Restricted
Review of TMI-2 resistance temperature detectors accident data and in-situ testing
Description
Since temperature measurements are a key to understanding the TMI-2 accident and subsequent plant conditions, survivability and performance of the 16 resistance temperature detectors (RTDs) in the reactor-building air-handling system have been investigated. This report describes that investigation, presents and analyzes the data recorded by the 16 RTDs during and after the accident, discusses in-situ tests conducted on the RTDs, and presents observations on the test results. 18 figures, 3 tables
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A03/MF A01 as DE83004265.
Files
Additional details
Publishing Information
- Imprint Pagination
- 29 p.
- Report number
- GEND-INF--024
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14754998
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- AIR; EXPERIMENTAL DATA; REACTOR ACCIDENTS; REACTOR INSTRUMENTATION; TEMPERATURE MEASUREMENT; THREE MILE ISLAND-2 REACTOR; TIME DEPENDENCE; VENTILATION
- Descriptors DEC
- ACCIDENTS; DATA; ENRICHED URANIUM REACTORS; FLUIDS; GASES; INFORMATION; NUMERICAL DATA; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS