Journal article

Analyze for the Quality Control of General X-ray Systems in Capital region

  • 1. Dept. of Radiological Technology, Shingu College, Seongnam (Korea, Republic of)
  • 2. Dept. of Nuclear Medicine, Severance Hospital, Seoul (Korea, Republic of)
  • 3. Dept. of Diagnostic Radiology, National Cancer Center, Seoul (Korea, Republic of)
  • 4. Dept. of Cadiology, Korea University Anam Hospital, Seoul (Korea, Republic of)
  • 5. Dept. of Radiologic Technology, Daegu Health College, Daegu (Korea, Republic of)

Description

Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

Additional details

Publishing Information

Journal Title
Journal of the Korean Society of Radiological Technology
Journal Volume
35
Journal Issue
2
Series
7 refs, 14 tabs
Journal Page Range
p. 93-102
ISSN
1226-2854

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
44015607
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
DIAGNOSIS; EDUCATIONAL FACILITIES; HOSPITALS; QUALITY CONTROL; RADIATION DOSES
Descriptors DEC
BUILDINGS; CONTROL; DOSES; MEDICAL ESTABLISHMENTS