A Survey of Organ Equivalent and Effective Doses from Diagnostic Radiology Procedures
Creators
- 1. Department of Physics and Astronomy, University of Waterloo, Waterloo, ON, N2L 3G1 (Canada)
- 2. Department of Medical Physics, Grand River Regional Cancer Center, Kitchener, ON, N2G 1G3 (Canada)
- 3. Department of Oncology, Queens University, Kingston, ON, K7L 5P9 (Canada)
- 4. Cancer Center of Southeastern Ontario, Kingston General Hospital, Kingston, ON, K7L 5P9 (Canada)
Description
The quantification of radiation risks associated with radiological examinations has been a subject of interest with the increased use of X-rays. Effective dose, which is a risk-weighted measure of radiation to organs in the body associated with radiological examination, is considered a good indicator of radiological risk. We have therefore investigated patient effective doses from radiological examinations. Organ and effective doses were estimated for 94 patients who underwent computed tomography examinations and for 338 patients who had conventional radiography examinations. The OrgDose (version 2) program was used for the estimation of effective doses. The tube potential ranges: 57 kVp to 138 kVp depending on the examination and patient size. The entrance surface doses have a wide range even for the same examination: 0.44–10.31 mGy (abdomen) and 0.66–16.08 mGy (lumbar spine) and the corresponding effective dose ranges 0.025–0.77 mSv and 0.025–0.95 mSv respectively. Effective dose for adult abdomen-pelvic CT examinations ranges 5.4–19.8 mSv with a mean of 13.6 mSv and for pediatrics ranges 2.1–5.5 mSv with a mean of 2.7 mSv. The mean effective dose for adult chest and head CT examinations are 7.9 and 1.8 mSv respectively and for pediatrics are 1.7 and 1.1 mSv
Availability note (English)
Available from http://dx.doi.org/10.5402/2013/204346; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4045519Additional details
Identifiers
Publishing Information
- Journal Title
- ISRN Radiology
- Journal Volume
- 2013
- Journal Page Range
- [0 p.]
- ISSN
- 2314-4084
INIS
- Country of Publication
- Egypt
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47028655
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ADULTS; COMPUTERIZED TOMOGRAPHY; DOSES; GEOCHEMICAL SURVEYS; GEOPHYSICAL SURVEYS; MARINE SURVEYS; PATIENTS; PEDIATRICS; PUBLIC OPINION; RADIOLOGY; VERTEBRAE; X RADIATION
- Descriptors DEC
- AGE GROUPS; BODY; DIAGNOSTIC TECHNIQUES; ELECTROMAGNETIC RADIATION; GEOLOGIC SURVEYS; IONIZING RADIATIONS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIATIONS; SKELETON; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2013 E. K. Osei and J. Darko.
- Notes
- PMCID: PMC4045519; PMID: 24977137; OAI: oai:pubmedcentral.nih.gov:4045519