We have developed a VME based BPM readout system with narrow band pass filters and 16-bit, 250 MSa/s ADCs and calibration pulse generators. The new system has wide dynamic range from 0.1 to 10 nC/bunch. The calibration pulse is used for the gain correction and the status monitor of the cable connection. The gain drift and the temperature dependence were measured by using the calibration pulse. The temperature dependence of the gain ratio of opposed electrode is less than 0.02%/°C. The system was very stable for the duration of a month. (author)

Part of:
Proceedings of the 12th annual meeting of Particle Accelerator Society of Japan

Additional details

Publishing Information

Imprint Title
Proceedings of the 12th annual meeting of Particle Accelerator Society of Japan
Imprint Pagination
1419 p.
Journal Page Range
p. 1255-1258

Conference

Title
12. annual meeting of Particle Accelerator Society of Japan
Dates
5-7 Aug 2015
Place
Tsuruga, Fukui (Japan)

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
48024948
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
BEAM DYNAMICS; CALIBRATION; ELECTRIC CHARGES; ELECTRIC FILTERS; ELECTRODES; ELECTRON DRIFT; KEK LINAC; PULSE GENERATORS; READOUT SYSTEMS; SPATIAL RESOLUTION; TEMPERATURE DEPENDENCE
Descriptors DEC
ACCELERATORS; DYNAMICS; ELECTRONIC EQUIPMENT; EQUIPMENT; FILTERS; FUNCTION GENERATORS; LINEAR ACCELERATORS; MECHANICS; RESOLUTION

Optional Information

Notes
3 refs., 6 figs.