Mass-resolving charge-exchange system on PDX
Description
The PDX charge-exchange system is comprised of four, ten channel, mass-resolved, charge-exchange analyzers. Each analyzer is constructed with parallel electric and magnetic fields and is calibrated over an energy range of 0.5 to 40 keV. The mass rejection between hydrogen and deuterium has been measured as better than 1000 to 1. For ohmic heated discharges the system can provide single shot radial ion temperature profiles (4 point) with 1 msec time resolution. For neutral beam heated discharges complete radial and temporal profiles can be obtained in 2 to 4 shots. The system is also equipped with a vertically aimed diagnostic neutral beam to allow local ion-energy distribution measurements. This report describes the analyzer system and its calibration, and presents results from ohmic and neutral beam heated discharges
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A04/MF A01 as DE83002336.Files
14744103.pdf
Files
(749.5 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:93f3d2c594f6232c6f1aa19ad1e95ac3
|
749.5 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 59 p.
- Report number
- PPPL--1940
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14744103
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ATOMIC BEAMS; CALIBRATION; CHARGE EXCHANGE; ELECTRIC FIELDS; ION TEMPERATURE; MAGNETIC FIELDS; PDX DEVICES; PLASMA DIAGNOSTICS
- Descriptors DEC
- BEAMS