Secondary Containment System component failure data analysis from 1984 to 1991
Creators
- 1. EG and G Idaho, Inc., Idaho Falls, ID (United States)
- 2. Los Alamos National Lab., NM (United States)
Description
This report gives the failure rates for the major tritium containing glovebox systems that comprise the Secondary Containment System at the Tritium systems Test Assembly, which is a fusion research and technology facility at the Los Alamos National Laboratory. The component failure reports, the numbers of components, and operating times or demands are all given in this report, and sample calculations of the binomial demand failure rates and poisson hourly failure rates are given in the appendices. The failure rates for these components form a solid data point based on actual operating experience, where there is very little published information. The eight years of nearly continuous Secondary Containment System operations should result in steady state failure rate values. These data should be useful for future fusion reactor design work and safety assessment tasks
Availability note (English)
MF available from INIS under the Report Number; OSTI as DE93001928; NTIS; INIS; US Govt. Printing Office Dep.
Files
Additional details
Publishing Information
- Imprint Pagination
- 66 p.
- Report number
- EGG-FSP--10323
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 24028615
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- CONTAINMENT SYSTEMS; DESIGN; GLOVEBOXES; MAINTENANCE; SAFETY ANALYSIS; SYSTEM FAILURE ANALYSIS; TRITIUM SYSTEMS TEST ASSEMBLY
- Descriptors DEC
- CONTAINMENT; ENGINEERED SAFETY SYSTEMS; EQUIPMENT; LABORATORY EQUIPMENT; SYSTEMS ANALYSIS; TEST FACILITIES
Optional Information
- Contract/Grant/Project number
- Contract AC07-76ID01570
- Funding organization
- USDOE, Washington, DC (United States).