Published March 1993
| Version v1
Journal article
SG (steam generator) tube repair by explosive welding
Description
Traditional joining techniques have limitations for bonding the ends of repair sleeves inside PWR cracked steam generator tubes. Explosive (kinetic) welding has been used as a successful alternative in over 5000 defective tubes. (author)
Additional details
Publishing Information
- Journal Title
- Nuclear Engineering International
- Journal Volume
- 38
- Journal Issue
- 464
- Journal Page Range
- p. 24, 26.
- ISSN
- 0029-5507
- CODEN
- NEINBF
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 24059649
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CRACKS; EXPLOSION WELDING; PWR TYPE REACTORS; REPAIR; STEAM GENERATORS; TUBES
- Descriptors DEC
- BOILERS; ENRICHED URANIUM REACTORS; FABRICATION; JOINING; POWER REACTORS; REACTORS; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; WELDING