Effect of working-fluid filling ratio and cooling-water flow rate on the performance of solar collector with closed-loop oscillating heat pipe
- 1. Korea Maritime University, Busan (Korea, Republic of)
Description
This study experimentally investigated the effect of the working-fluid filling ratio (FR) and the cooling-water flow rate (CWFR) on the top heat loss and the performance of a solar collector equipped with a closed-loop oscillating heat pipe (CLOHP). The CLOHP was composed of a heating section, a cooling section, and an adiabatic section; it had a 0.002-m internal diameter and eight turns. The heating section was attached to a copper plate coated with black chrome, which absorbed energy from a solar simulator that had 12 halogen lamps and was controlled by a voltage regulator. The cooling section was inserted into the collector's cooling box, which was made of a transparent acrylic plate. The FR of the working fluid ranged from 30% to 80% with a 10% interval, and the CWFRs were 0.15 l/min, 0.30 l/min, and 0.45 l/min. The experimental results show that the solar collector equipped with the CLOHP has good performance at working-fluid FRs of 60% and 70% with low flow rates of 0.15 l/min and 0.30 l/min
Additional details
Publishing Information
- Journal Title
- Journal of Mechanical Science and Technology
- Journal Volume
- 26
- Journal Issue
- 1
- Series
- 13 refs, 10 figs
- Journal Page Range
- p. 251-258
- ISSN
- 1738-494X
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 44015529
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- COOLING; FLOW RATE; HEAT LOSSES; PERFORMANCE; PIPES; SOLAR COLLECTORS
- Descriptors DEC
- ENERGY LOSSES; ENERGY TRANSFER; EQUIPMENT; HEAT TRANSFER; LOSSES; SOLAR EQUIPMENT; TUBES