Published February 1974 | Version v1
Journal article

Measurements of UF6 cylinders with portable instruments

  • 1. Los Alamos Scientific Lab., NM

Description

AbstractThe applicability of portable instruments for rapid nondestructive verification of the enrichment of UF6 in cylinders has been tested on a large number of Types-30 and -5A cylinders. Three basic techniques were used: (a) gamma-ray counting with NaI, combined with ultrasonic measurement of cylinder wall thickness, (b) passive-neutron counting, and (c) active-neutron interrogation with thermal neutrons from a radioactive neutron source. The accuracy of the gamma-ray method was ∼5% (1σ) for Type-30 cylinders of UF6 and 2% for highly enriched UF6 in Type-5A cylinders; however, the method occasionally failed for Type-30 cylinders because of background from nonvolatile daughters of 238U plated on the cylinder walls. The standard deviation of enrichments of 110 Type-30 cylinders, derived from passive-neutron counting data by assuming a constant 235U/234U ratio, is 6%. The response of the active system increases almost linearly with enrichment up to ∼2.5% 235U and then saturates at ∼4%.

Additional details

Identifiers

Publishing Information

Journal Title
Nuclear Technology
Journal Volume
21
Journal Issue
2
Series
Nucl. Technol.
Journal Page Range
133-148
ISSN
0029-5450

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent