Published 1983 | Version v1
Miscellaneous

Experimental method to measure dose equivalent indices for low and medium energy X-rays

  • 1. Instituto de Radioprotecao e Dosimetria, Rio de Janeiro (Brazil)

Description

An experimental method was developed to measure Dose Equivalent Indices for low and medium energy X-rays. A sphere was constructed to simulate the human body in accordance with ICRU Report 19 but using plexiglas instead of tissue equivalent material of density 1g. cm-3. (E.G.)

Abstract (Portuguese)

Desenvolveu-se um metodo experimental para medir indices de doses equivalentes para radiacao X de baixa e media energia. Construiu-se uma esfera para simular o corpo humano em acordo com o relatorio 19 da ICRU, mas usando 'plexiglas' ao inves do material equivalente do tecido de densidade 1g. cm-3. (E.G.)

Additional details

Publishing Information

Imprint Title
Proceedings of the Meeting on Radiological Protection and Dosimetry
Imprint Pagination
330 p.
Journal Page Range
p. 204-205.
Report number
INIS-BR--86

Conference

Title
Meeting on Radiological Protection and Dosimetry.
Dates
21-26 Mar 1983.
Place
Itaipava, RJ (Brazil).