Quality control of technetium-99m DTPA: correlation of analytic tests with in vivo protein binding in man
Description
When [/sup 99m/Tc]DTPA is administered, a small fraction of the activity (presumably an impurity) is bound to plasma proteins. This causes an error in the calculation of glomerular filtration rate from plasma clearance. This paper presents two methods of laboratory quality control for measuring the fraction that binds to plasma proteins. One method involves in vitro binding to human serum albumin followed by gel filtration. The other method involves descending paper chromatography on wet pre-equilibrated anion exchange paper. In a series of 80 patients, correlation was demonstrated between laboratory characteristics and actual clinical performance of the [/sup 99m/Tc]DTPA preparation. Both laboratory methods appear suitable for routine quality control
Additional details
Publishing Information
- Journal Title
- J. Nucl. Med.
- Journal Issue
- no.4
- Series
- J. Nucl. Med.
- ISSN
- 0022-3123
- CODEN
- JNMEA
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 18013843
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- DTPA; ERRORS; IMPURITIES; KIDNEYS; PATIENTS; QUALITY CONTROL; RADIOPHARMACEUTICALS; RENAL CLEARANCE; TECHNETIUM 99
- Descriptors DEC
- AMINO ACIDS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; CARBOXYLIC ACIDS; CHELATING AGENTS; CLEARANCE; CONTROL; DRUGS; EXCRETION; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTO; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LABELLED COMPOUNDS; MATERIALS; NUCLEI; ODD-EVEN NUCLEI; ORGANIC ACIDS; ORGANIC COMPOUNDS; ORGANS; RADIOACTIVE MATERIALS; RADIOISOTOPES; RADIOPROTECTIVE SUBSTANCES; RESPONSE MODIFYING FACTORS; TECHNETIUM ISOTOPES; YEARS LIVING RADIOISOTOPES