Feasibility of using thermal response to Ka band millimeter wave heating to assess skin blood flow
- 1. Mechanical Engineering Department, University of South Alabama, Mobile, AL 36688 (United States)
- 2. Chemical and Biomolecular Engineering Department, University of South Alabama, Mobile, AL 36688 (United States)
- 3. Physiology and Cell Biology Department, University of South Alabama, Mobile, AL 36688 (United States)
Description
Objective: Implementation of clinical guidelines for diagnosing peripheral artery disease will demand screening many millions of patients who are considered at-risk. This will require faster, easier screening technologies to identify patients with compromised blood flow to the extremities. Approach: The feasibility of using surface temperature response to Ka band (26.5–40 GHz) near-field irradiation to assess skin blood flow was explored using an animal model. Ears of domestic rabbits were subjected to low-power continuous wave radio frequency heating from an open-ended waveguide (WR-28) at f = 35 GHz. Three flow conditions were evaluated: (1) a baseline flow condition, (2) occluded flow and (3) reactive hyperemia. Surface temperatures were monitored continuously by means of an infrared thermography camera during each 2 min exposure. Main results: Ensemble average results showed significant differences (p < .05) at exposure times 30, 60, 90 and 120 s between baseline and occluded conditions, and between baseline and reactive hyperemia conditions. The occluded condition (N = 12) resulted in an average temperature increase of 21.4 °C ± 3.9 after 2 min, compared with an average increase of 12.1 °C ± 1.6 for baseline conditions (N = 9) and 4.7 °C ± 3.6 for post-occlusion/hyperemic conditions (N = 8). Significance: Results are compared with the results of a simple two parameter mathematical model. These results suggest a method for non-invasive skin blood flow assessment to screen for peripheral artery disease and associated risk of cardiovascular events. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1361-6579/aab4d4Additional details
Identifiers
Publishing Information
- Journal Title
- Physiological Measurement (Print)
- Journal Volume
- 39
- Journal Issue
- 4
- Journal Page Range
- [9 p.]
- ISSN
- 0967-3334
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 51084004
- Subject category
- S60: APPLIED LIFE SCIENCES;
- Descriptors DEI
- ARTERIES; AUDITORY ORGANS; BLOOD FLOW; DISEASES; GHZ RANGE; HEATING; INFRARED THERMOGRAPHY; PATIENTS; RABBITS; RADIOWAVE RADIATION; SKIN
- Descriptors DEC
- ANIMALS; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; ELECTROMAGNETIC RADIATION; FREQUENCY RANGE; MAMMALS; MEASURING METHODS; ORGANS; RADIATIONS; SENSE ORGANS; THERMOGRAPHY; VERTEBRATES