Published 1990 | Version v1
Journal article

Influence of high temperature annealing on TL response of CaF2:Tm

  • 1. National Tsing Hua Univ., Hsinchu, Taiwan (China)

Description

The high temperature annealing treatment given to CaF2:Tm phosphor from 1000C to 8000C is described. The thermoluminescent (TL) properties were investigated by studying the residual TL, its sensitivity and glow curve at different annealing treatments. The experimental results indicate that (1) there is no difference in the TL output for annealing temperatures less than 4000C, (2) the TL sensitivity decreases as the annealing temperature increases, and (3) the low temperature peak shifts to the low temperature region and the high temperature peak shifts to the high temperature region as the annealing temperature increases. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
33
Journal Issue
1-4
Series
Radiat. Prot. Dosim.
Journal Page Range
189-191
ISSN
0144-8420
CODEN
RPDOD

Conference

Title
9. International conference on solid state dosimetry.
Dates
6-10 Nov 1989.
Place
Vienna (Austria).

Optional Information

Notes
Vol. 1 of 2 vols. Vol. 2 published in Radiat. Prot. Dosim. (1990) v. 34(1-4).
Secondary number(s)