Published 1994
| Version v1
Report
The assessment of heat transport circuit: Contamination at Candu 600 reactor
Creators
- 1. Institute for Power Studies and Design Nuclear Department, Bucharest-Magurele (Romania)
Description
The radioactive contamination of inner surfaces of the PHT circuit in normal operation is being produced by deposits from the coolant (D2O) of activated and fission products. In order to determine the modifications of circuit contamination that can arise by changing the standard operation parameters, preliminary calculations have been effected taking into account the determinative physico-chemical parameters
Additional details
Publishing Information
- Imprint Title
- Technology and programs for Radioactive Waste Management and Environmental Restoration. Volume 3
- Imprint Pagination
- 857 p.
- Journal Page Range
- p. 1775-1780.
- Report number
- CONF-940225--Vol.3
Conference
- Title
- working towards a cleaner environment.
- Acronym
- Waste management '94
- Dates
- 27 Feb - 3 Mar 1994.
- Place
- Tucson, AZ (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 27015664
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CANDU TYPE REACTORS; CONTAMINATION; CORROSION PRODUCTS; DEPOSITS; FISSION PRODUCTS; HEAVY WATER; REACTOR COOLING SYSTEMS; REACTOR TECHNOLOGY
- Descriptors DEC
- COOLING SYSTEMS; HEAVY WATER MODERATED REACTORS; HYDROGEN COMPOUNDS; ISOTOPES; MATERIALS; OXYGEN COMPOUNDS; POWER REACTORS; PRESSURE TUBE REACTORS; RADIOACTIVE MATERIALS; REACTOR COMPONENTS; REACTORS; THERMAL REACTORS; WATER