The assessment of heat transport circuit: Contamination at Candu 600 reactor

  • 1. Institute for Power Studies and Design Nuclear Department, Bucharest-Magurele (Romania)

Description

The radioactive contamination of inner surfaces of the PHT circuit in normal operation is being produced by deposits from the coolant (D2O) of activated and fission products. In order to determine the modifications of circuit contamination that can arise by changing the standard operation parameters, preliminary calculations have been effected taking into account the determinative physico-chemical parameters

Additional details

Publishing Information

Imprint Title
Technology and programs for Radioactive Waste Management and Environmental Restoration. Volume 3
Imprint Pagination
857 p.
Journal Page Range
p. 1775-1780.
Report number
CONF-940225--Vol.3

Conference

Title
working towards a cleaner environment.
Acronym
Waste management '94
Dates
27 Feb - 3 Mar 1994.
Place
Tucson, AZ (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
27015664
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CANDU TYPE REACTORS; CONTAMINATION; CORROSION PRODUCTS; DEPOSITS; FISSION PRODUCTS; HEAVY WATER; REACTOR COOLING SYSTEMS; REACTOR TECHNOLOGY
Descriptors DEC
COOLING SYSTEMS; HEAVY WATER MODERATED REACTORS; HYDROGEN COMPOUNDS; ISOTOPES; MATERIALS; OXYGEN COMPOUNDS; POWER REACTORS; PRESSURE TUBE REACTORS; RADIOACTIVE MATERIALS; REACTOR COMPONENTS; REACTORS; THERMAL REACTORS; WATER