45-Day safety screen results for tank 241-U-203, push mode, cores 79 and 80

Description

Two one-segment core samples from tank 241-U-203 (U-203) were received by the 222-S Laboratories and underwent safety screening analysis, consisting of differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha activity. In addition to the safety screening requirements, inductively coupled plasma (ICP) spectrographic analysis for lithium was performed to determine the extent of hydrostatic head fluid contamination during the sampling event. No notification limits were exceeded for these analyses

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95012837; NTIS; US Govt. Printing Office Dep.

Files

26074351.pdf

Files (1.2 MB)

Name Size Download all
md5:7fbd30363e14dbef28a335d0baeb71bc
1.2 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
38 p.
Report number
WHC-SD--WM-DP-109

Optional Information

Contract/Grant/Project number
Contract AC06-87RL10930
Funding organization
USDOE, Washington, DC (United States).