Published 2002
| Version v1
Miscellaneous
Response characteristics of a transmission line based transformer
Description
Response characteristics of a transmission line based transformer were studied to take into account signals that inevitably appear in the space outside of the transmission lines. A prototype of the transformer, using semi-rigid co-axial cables, was constructed and tested to confirm the results of the theory. Good agreement was obtained between the theory and experiments in the 5 MHz to 3 GHz frequency range. A 3 dB bandwidth of this transformer was also obtained from about 20 MHz to 1 GHz. (author)
Additional details
Identifiers
Publishing Information
- Imprint Title
- Proceedings of the 27th linear accelerator meeting in Japan
- Imprint Pagination
- 412 p.
- Journal Page Range
- p. 48-50
Conference
- Title
- 27. linear accelerator meeting in Japan
- Dates
- 7-9 Aug 2002
- Place
- Kyoto (Japan)
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 53064190
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ACCELERATORS; COAXIAL CABLES; ELECTRIC COILS; FREQUENCY CONTROL; FREQUENCY DEPENDENCE; FREQUENCY MEASUREMENT; FREQUENCY RANGE; POWER TRANSMISSION LINES; PULSE TECHNIQUES; RESPONSE FUNCTIONS; TRANSFORMERS
- Descriptors DEC
- CABLES; CONDUCTOR DEVICES; CONTROL; ELECTRIC CABLES; ELECTRICAL EQUIPMENT; EQUIPMENT; FUNCTIONS
Optional Information
- Notes
- 5 refs., 3 figs.; This record replaces 34017428