Response characteristics of a transmission line based transformer

Creators

  • 1. Hokkaido Univ., Faculty of Engineering, Sapporo, Hokkaido (Japan)

Description

Response characteristics of a transmission line based transformer were studied to take into account signals that inevitably appear in the space outside of the transmission lines. A prototype of the transformer, using semi-rigid co-axial cables, was constructed and tested to confirm the results of the theory. Good agreement was obtained between the theory and experiments in the 5 MHz to 3 GHz frequency range. A 3 dB bandwidth of this transformer was also obtained from about 20 MHz to 1 GHz. (author)

Part of:
Proceedings of the 27th linear accelerator meeting in Japan

Additional details

Publishing Information

Imprint Title
Proceedings of the 27th linear accelerator meeting in Japan
Imprint Pagination
412 p.
Journal Page Range
p. 48-50

Conference

Title
27. linear accelerator meeting in Japan
Dates
7-9 Aug 2002
Place
Kyoto (Japan)

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
53064190
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCELERATORS; COAXIAL CABLES; ELECTRIC COILS; FREQUENCY CONTROL; FREQUENCY DEPENDENCE; FREQUENCY MEASUREMENT; FREQUENCY RANGE; POWER TRANSMISSION LINES; PULSE TECHNIQUES; RESPONSE FUNCTIONS; TRANSFORMERS
Descriptors DEC
CABLES; CONDUCTOR DEVICES; CONTROL; ELECTRIC CABLES; ELECTRICAL EQUIPMENT; EQUIPMENT; FUNCTIONS

Optional Information

Notes
5 refs., 3 figs.; This record replaces 34017428