Studies of an X-band three-cavity gyroklystron with penultimate cavity tuning

  • 1. Univ. of Maryland, College Park (United States)

Description

The authors present experimental results of a 10 GHz TE01 mode three-cavity gyroklystron. The beam is produced by a pulse line modulator and magnetron injection gun, which can operate to 433 kV and 225 A with 1 μs flat-top and at a rep rate of 3Hz. Microwave power is measured by a mode-selective directional coupler and flowing methanol calorimeter. Mode purity is determined by a large anechoic chamber. Initial testing of the first three-cavity circuit has produced a peak power of 23 MW with efficiency of 27% and pulse energy of 36J. They have a maximum gain of 39 dB at a peak power of 21 MW

Additional details

Publishing Information

Imprint Title
Conference record of the 1991 IEEE particle accelerator conference: Accelerator science and technology. Volume 2 of 5
Imprint Pagination
724 p.
Journal Page Range
p. 731-733.
Report number
DOE/ER/40607--1-Vol.2

Conference

Title
1991 Institute of Electrical and Electronics Engineers (IEEE) particle accelerator conference (PAC).
Dates
6-11 May 1991.
Place
San Francisco, CA (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
24011164
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Numerical Data, Non-conventional Literature
Descriptors DEI
COLLIDING BEAMS; EFFICIENCY; EXPERIMENTAL DATA; FEASIBILITY STUDIES; KLYSTRONS; LINEAR ACCELERATORS; MAGNETRONS; MICROWAVE AMPLIFIERS; OPERATION; PERFORMANCE TESTING; POWER; POWER SUPPLIES; RF SYSTEMS; STABILITY; TIME DEPENDENCE
Descriptors DEC
ACCELERATORS; AMPLIFIERS; BEAMS; DATA; ELECTRON TUBES; ELECTRONIC EQUIPMENT; EQUIPMENT; INFORMATION; MICROWAVE EQUIPMENT; MICROWAVE TUBES; NUMERICAL DATA; TESTING

Optional Information

Secondary number(s)
CONF-910505--Vol.2.