Published 1987 | Version v1
Book

High resolution 64-element pyroelectric linear array IR detector

  • 1. Royal Signals and Radar Establishment, Malvern (England)

Description

A 64-element pyroelectric linear array detector has been developed. Included within the detector is a corresponding array of source followers together with a multiplexer and amplifier. High responsivity and high detectivity have been achieved, together with a low level of microphony

Additional details

Publishing Information

Publisher
Society of Photo-Optical Instrumentation Engineers.
Imprint Place
Bellingham, WA (USA)
Imprint Title
Passive infrared systems and technology; Proceedings of the Meeting, The Hague, Netherlands, Mar. 31-Apr. 1, 1987
Journal Page Range
p. 92-97.

Conference

Title
Passive infrared systems and technology meeting.
Dates
31 Mar - 1 Apr 1987.
Place
The Hague (Netherlands).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
20016724
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AMPLIFIERS; FIELD EFFECT TRANSISTORS; INFRARED RADIATION; MULTIPLEXERS; NOISE; RADIATION DETECTORS; SEMICONDUCTOR MATERIALS; SPECIFICATIONS
Descriptors DEC
ELECTROMAGNETIC RADIATION; ELECTRONIC EQUIPMENT; EQUIPMENT; MATERIALS; MEASURING INSTRUMENTS; RADIATIONS; SEMICONDUCTOR DEVICES; TRANSISTORS