Testing the fast-response neutron measuring channel on base of rhodium self-powered detector the AMB-200 reactor

Description

Tests of the fast-response neutron measuring channel based on the rhodium self-powered detector with electronic correction of detector response lag carried out in the AMB-200 reactor have shown that the channel response lag doesn't exceed 0.15s and it is applicable for monitoring transients in the reactor and that spatial effects in reactivity measurements are considerable and require account and suppression

Additional details

Additional titles

Original title (Russian)
Испытания малоинерционного нейтронного измерительного канала на основе родиевого DPZ в AMB-200

Publishing Information

Journal Title
Atomnaya Ehnergiya
Journal Volume
68
Journal Issue
2
Series
At. Ehnerg.
Journal Page Range
101-104
ISSN
0004-7163