Published 2020 | Version v1
Journal article

Calculation of gamma-ray attenuation parameters for aluminium, iron, zirconium, and tungsten

  • 1. Department of Physics, College of Science, University of Raparin, Sulaimanyah, Iraqi Kurdistan (Iraq)

Description

The purpose of this study was to determine the linear attenuation coefficient, the mass attenuation coefficient, Half Value Layer. Tenth Value Layer and Mean Free Path for four different shielding materials such as aluminium, iron, zirconium and tungsten. By using the gamma-radiation energies emitted from 152Eu, 22Na, 137Cs, and 60Co radioactive sources. For this purpose, the attenuation measurements were performed using NaI(TI) detector. Calculated values of all parameters of the all shielding materials were compared with each other. The results of all presented parameters show that, tungsten has the best radiation shielding compared to other shielding materials. Then, the obtained parameters were compared with the theoretical values. (author)

Additional details

Publishing Information

Journal Title
Voprosy Atomnoj Nauki i Tekhniki
Journal Issue
no.5-129
Journal Page Range
p. 60-65
ISSN
1562-6016