Digital radiography: optimization of image quality and dose using multi-frequency software
- 1. University College Lillebelt, Conrad Research Center, Odense (Denmark)
- 2. University of Southern Denmark, Research Unit of Health Economics, Odense (Denmark)
- 3. Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark)
- 4. University of Bergen, Institute of Surgical Sciences, Bergen (Norway)
- 5. Haukeland University Hospital, Section of Pediatric Radiology, Bergen (Norway)
- 6. Medical Radiation Physics, Department of Clinical Sciences, Malmoe (Sweden)
- 7. Skaane University Hospital, Lund University (Sweden)
- 8. Gjoevik University College, Gjoevik (Norway)
Description
New developments in processing of digital radiographs (DR), including multi-frequency processing (MFP), allow optimization of image quality and radiation dose. This is particularly promising in children as they are believed to be more sensitive to ionizing radiation than adults. To examine whether the use of MFP software reduces the radiation dose without compromising quality at DR of the femur in 5-year-old-equivalent anthropomorphic and technical phantoms. A total of 110 images of an anthropomorphic phantom were imaged on a DR system (Canon DR with CXDI-50 C detector and MLT[S] software) and analyzed by three pediatric radiologists using Visual Grading Analysis. In addition, 3,500 images taken of a technical contrast-detail phantom (CDRAD 2.0) provide an objective image-quality assessment. Optimal image-quality was maintained at a dose reduction of 61% with MLT(S) optimized images. Even for images of diagnostic quality, MLT(S) provided a dose reduction of 88% as compared to the reference image. Software impact on image quality was found significant for dose (mAs), dynamic range dark region and frequency band. By optimizing image processing parameters, a significant dose reduction is possible without significant loss of image quality. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00247-012-2385-3Additional details
Identifiers
Publishing Information
- Journal Title
- Pediatric Radiology
- Journal Volume
- 42
- Journal Issue
- 9
- Journal Page Range
- p. 1112-1118
- ISSN
- 0301-0449
- CODEN
- PDRYA5
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 43107509
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CHILDREN; COMPUTER CODES; DIAGNOSIS; DIGITAL SYSTEMS; FEMUR; IMAGE PROCESSING; OPTIMIZATION; PEDIATRICS; PHANTOMS; QUALITY ASSURANCE; RADIATION DOSES; REGRESSION ANALYSIS; X-RAY RADIOGRAPHY
- Descriptors DEC
- AGE GROUPS; ANIMALS; BODY; DIAGNOSTIC TECHNIQUES; DOSES; INDUSTRIAL RADIOGRAPHY; MAMMALS; MAN; MATERIALS TESTING; MATHEMATICS; MEDICINE; MOCKUP; NONDESTRUCTIVE TESTING; NUCLEAR MEDICINE; ORGANS; PRIMATES; PROCESSING; RADIOLOGY; SKELETON; STATISTICS; STRUCTURAL MODELS; TESTING; VERTEBRATES