Published January 1989
| Version v1
Journal article
Precision of determining compliance with prescribed fields from conventional portal films
Creators
- 1. Manitoba Cancer Treatment and Research Foundation, Winnipeg (Canada)
Description
Three hundred and seventy measurements of field placement errors (FPEs) have been made by a total of 16 observers on 20 prescription-treatment film pairs taken during routine radiotherapy for cancer of the prostate. Analysis of the distributions of the measured FPEs has yielded the precision of the measurement under a variety of conditions. We report here the influence on the precision of determining FPEs of the following factors: the clinical duties of the observers, the quality of the treatment film, the relative magnification of prescription and treatment films, and whether double-exposure techniques were employed. (author)
Additional details
Publishing Information
- Journal Title
- British Journal of Radiology
- Journal Volume
- 62
- Journal Issue
- 733
- Series
- Br. J. Radiol.
- Journal Page Range
- 48-52
- ISSN
- 0007-1285
- CODEN
- BJRAA
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 20029775
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ERRORS; NEOPLASMS; PHOTOGRAPHIC FILMS; PROSTATE; QUALITY CONTROL; RADIOTHERAPY; SPATIAL DOSE DISTRIBUTIONS
- Descriptors DEC
- BODY; CONTROL; DISEASES; DISTRIBUTION; GLANDS; MALE GENITALS; MEDICINE; ORGANS; RADIATION DOSE DISTRIBUTIONS; SPATIAL DISTRIBUTION; THERAPY