Published December 2008 | Version v1
Journal article

Measurement and comparison of skin dose for prostate and head-and-neck patients treated on various IMRT delivery systems

  • 1. Department of Radiology, University of Texas Health Science Center at San Antonio, 7703 Floyd Curl Dr., San Antonio, TX 78229 (United States)
  • 2. Department of Medical Physics and Radiotherapy, Cancer Therapy and Research Center, 7979 Wurzbach Road, San Antonio, TX 78229 (United States)

Description

Treatment planning systems inaccurately quantify dose deposited to the skin in the course of radiotherapy owing to their inability to properly account for all the surface dose contributing factors. In this work, we describe a technique for accurately measuring skin dose using ultra-thin thermoluminescent dosimeters and EBT gafchromic films. We investigated the variation in average skin dose for prostate and head-and-neck patients undergoing radiotherapy on three IMRT systems including serial/helical tomotherapy, and IMRT-step and shoot system. Helical tomotherapy was observed to deposit the highest average skin dose followed by serial tomotherapy delivery system

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2008.05.003

Additional details

Identifiers

DOI
10.1016/j.apradiso.2008.05.003;
PII
S0969-8043(08)00281-9;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
66
Journal Issue
12
Journal Page Range
p. 1844-1849
ISSN
0969-8043
CODEN
ARISEF

Optional Information

Copyright
Copyright (c) 2008 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.