Published July 1988 | Version v1
Journal article

Pseudotomographic fitting algorithm for density profile reconstruction from a sparse 1-D interferometer array

  • 1. Plasma Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139

Description

An algorithm has been developed for fast analysis of a sparse multichord interferometer array, yielding peak density, Gaussian width, radial offset, ellipticity, and instability amplitude and frequency from line-integrated density measurements. A nonlinear least-squares fit is performed over many short time intervals, with independent variables reduced to one dimension. Assumptions of plasma rigidity and slowly evolving rotation rate are necessary to trade temporal resolution (on instability timescales) for spatial resolution across the moving plasma column. Results from the Tara tandem mirror experiment are shown

Additional details

Publishing Information

Journal Title
Rev. Sci. Instrum.
Journal Volume
59
Journal Issue
7
Series
Rev. Sci. Instrum.
Journal Page Range
1067-1071
ISSN
0034-6748
CODEN
RSINA