Quantum pendants: Assessing exposure dose and concurrent radiation hazard
Creators
- 1. Saudi Aramco, Environmental Protection Department (Saudi Arabia)
- 2. Department of Physics, College of Education, University of Sulaimani, Sulaimani, 46001, Kurdistan (Iraq)
- 3. Department of Physics Faculty of Science, Universiti Teknologi Malaysia, Johor, 81310, UTM, Skudai (Malaysia)
Description
Scalar energy pendants are widely accessible, and their sellers claim that they enhance the body energy flow, restore energy levels, and help maintain health and well-being. This study conducted radiological assessments of six pendants coded as QP1-QP6, including measurement of equivalent dose rates using a portable dose rate meter and software, assessment of the surface contamination, and a wipe test for removable contamination. Skin dose measurements were conducted using thermoluminescence dosimetry, and high-resolution gamma-ray spectrometry analysis was conducted. The committed effective dose (CED) of radionuclides ingested was also calculated based on the International Commission on Radiological Protection Publication 119 Compendium of Dose Coefficients, and the activity concentrations from the pendants were compared with the International Atomic Energy Agency (IAEA) SSG-36 report. Sample QP1 demonstrated a maximum external effective dose of 0.3 μSv/h and a contamination level of 91.0 counts per second of contact. The wipe test for removable contamination indicated no reading above the background level for any of the six pendants. Gamma spectroscopy revealed that Uranium-238 and Thorium-232 activity were highest in QP1 at 7.5 and 52.4 Bq/g and lowest in QP2 at 2.3 and 16.5 Bq/g, respectively. The identified specific activities were above the IAEA exemption limit of 1 Bq/g for naturally occurring Uranium-238 and Thorium-232. The CED calculations indicated that ingestion of these samples contributes less than 1.0 mSv/year, which can be viewed as negligible. However, the pendants showed doses several times higher than the IAEA limit of 10 μSv/year for consumer products. In conclusion, scalar energy pendants provide an unnecessary radiation dose to wearers, and regularly wearing these products may be associated with chronic receipt of low-dose-rate radiation. This study recommend member of the public to be aware of such product and been banned from circulation to the public
Additional details
Publishing Information
- Journal Title
- Journal of Radiation Research and Applied Sciences
- Journal Volume
- 17
- Journal Issue
- 1
- Journal Page Range
- 6 p.
- ISSN
- 1687-8507
INIS
- Country of Publication
- Egypt
- Country of Input or Organization
- Egypt
- INIS RN
- 55053133
- Subject category
- S54: ENVIRONMENTAL SCIENCES;
- Descriptors DEI
- EARTH CRUST; ENVIRONMENT; HIGH-PURITY GE DETECTORS; PUBLIC HEALTH; RADIATION DOSES; RADON 220; RADON 222; THERMOLUMINESCENT DOSIMETRY; THORIUM 232; URANIUM 238
- Descriptors DEC
- ACTINIDE NUCLEI; ALPHA DECAY RADIOISOTOPES; DAYS LIVING RADIOISOTOPES; DOSES; DOSIMETRY; EVEN-EVEN NUCLEI; GE SEMICONDUCTOR DETECTORS; HEAVY NUCLEI; ISOTOPES; MEASURING INSTRUMENTS; NUCLEI; RADIATION DETECTORS; RADIOISOTOPES; RADON ISOTOPES; SECONDS LIVING RADIOISOTOPES; SEMICONDUCTOR DETECTORS; SPONTANEOUS FISSION RADIOISOTOPES; THORIUM ISOTOPES; URANIUM ISOTOPES; YEARS LIVING RADIOISOTOPES