Particle contamination in a cleanroom is very complex with a complicated process and several pieces of spreading equipment. Detailed information on the locations of the contamination sources and the path of the contamination is needed for economical and efficient control of the contaminant particles in such a cleanroom. An allocation method was developed to quantitatively predict the contamination generated from the pollution sources. In this paper, we propose a zoning method to accelerate the computation time for estimating the contributions. Our results showed that we can quantitatively estimate the amount of contamination generated from pollution sources.
Additional details
Publishing Information
- Journal Title
- Transactions of the Korean Society of Mechanical Engineers. B
- Journal Volume
- 39
- Journal Issue
- 3
- Series
- 8 refs, 12 figs
- Journal Page Range
- p. 253-260
- ISSN
- 1226-4881
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 46110818
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- CLEAN ROOMS; CONTAINMENT; CONTROL; EQUIPMENT; POLLUTION; TURBULENCE