Published March 2015 | Version v1
Journal article

Zoning Method to Predict Contaminant Sources in Turbulent-Type Cleanroom

  • 1. Sungkyunkwan University, Seoul (Korea, Republic of)
  • 2. Korea Marine Equipment Research Institute, Seoul (Korea, Republic of)

Description

Particle contamination in a cleanroom is very complex with a complicated process and several pieces of spreading equipment. Detailed information on the locations of the contamination sources and the path of the contamination is needed for economical and efficient control of the contaminant particles in such a cleanroom. An allocation method was developed to quantitatively predict the contamination generated from the pollution sources. In this paper, we propose a zoning method to accelerate the computation time for estimating the contributions. Our results showed that we can quantitatively estimate the amount of contamination generated from pollution sources.

Additional details

Publishing Information

Journal Title
Transactions of the Korean Society of Mechanical Engineers. B
Journal Volume
39
Journal Issue
3
Series
8 refs, 12 figs
Journal Page Range
p. 253-260
ISSN
1226-4881

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
46110818
Subject category
S42: ENGINEERING;
Descriptors DEI
CLEAN ROOMS; CONTAINMENT; CONTROL; EQUIPMENT; POLLUTION; TURBULENCE