Published 1996 | Version v1
Book

Assessment of effective dose and uterus dose for workers in medical radiology

  • 1. Centre for Radiation Protection, Eindhoven Univ. of Technology, POB 513, 5600 MB Eindhoven (Netherlands)

Description

Using model calculations for X-ray shielding and dosimetry, we analyzed the protective effect of lead aprons on the effective dose and organ doses to workers in medical radiology. We investigated the relationship between effective dose and personal dose measurements. Our study enables the choice of appropriate correction factors for converting depth dose measurements into effective dose, for typical exposure situations in medical radiology. In consideration of protection of the conceptus, we give guidance on the control of the equivalent dose to the uterus. (author)

Part of:
IRPA9: 1996 international congress on radiation protection. Proceedings. Volume 3

Additional details

Publishing Information

Publisher
Berger.
Imprint Place
Horn (Austria)
ISBN
3-9500255-4-5
Imprint Title
IRPA9: 1996 international congress on radiation protection. Proceedings. Volume 3
Imprint Pagination
697 p.
Journal Page Range
p. 531-533.

Conference

Title
9. international congress on radiation protection and general assem bly of the International Radiation Protection Association (IRPA).
Dates
14-19 Apr 1996.
Place
Vienna (Austria).

INIS

Country of Publication
Austria
Country of Input or Organization
Austria
INIS RN
28059137
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DOSE EQUIVALENTS; DOSIMETRY; ICRP; KERMA; MEDICAL SURVEILLANCE; MONTE CARLO METHOD; RADIATION DOSES; RADIATION PROTECTION; RISK ASSESSMENT; SHIELDING; UTERUS; X RADIATION
Descriptors DEC
BODY; CALCULATION METHODS; ELECTROMAGNETIC RADIATION; FEMALE GENITALS; INTERNATIONAL ORGANIZATIONS; IONIZING RADIATIONS; ORGANS; RADIATIONS

Optional Information