Depth dependence of the single chamber response function of the I'mRT MatriXX array in a 6 MV photon beam
- 1. Universiti Sains Malaysia, Penang (Malaysia). School of Physics
- 2. Qassim Univ. (Saudi Arabia). Dept. of Physics
- 3. Mt Miriam Hospital, Penang (Malaysia)
Description
One of the factors which influence the spatial resolution of a 2D detector array is the size of the single detector, another the transport of the secondary electrons from the walls into the measuring volume. In this study, the single ion chamber dose response function of an I'mRT MatriXX array was determined by comparison between slit beam dose profiles measured with the array and with EBT2 radiochromic film in a solid water-equivalent phantom at a shallow depth of 0.5 cm and at a depth of 5 cm beyond the depth dose maximum for a 6 MV photon beam. The dose response functions were obtained using two methods, the best fit method and the deconvolution method. At the shallow depth, a Lorentz function and at 5 cm depth a Gaussian function, both with the same FWHM of 7.4 mm within limits of uncertainty, were identified as the best suited dose response functions of the 4.5 mm diameter single array chamber. These dose response functions were then tested on various dose profiles whose true shape had been determined with EBT2 film and with the IC03 ionization chamber. By convolving these with the Lorentz kernel (at shallow depth) and the Gaussian kernel (at 5 cm depth) the signal profiles measured with the I'mRT MatriXX array were closely approximated. Thus, the convolution of TPS-calculated dose profiles with these dose response functions can minimize the differences between calculation and measurement which occur due to the limited spatial resolution of the I'mRT MatriXX detector. (orig.)
Additional details
Publishing Information
- Journal Title
- Zeitschrift fuer Medizinische Physik
- Journal Volume
- 23
- Journal Issue
- 4
- Journal Page Range
- p. 270-278
- ISSN
- 0939-3889
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 45021698
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- BEAM PROFILES; DEPTH DOSE DISTRIBUTIONS; DOSE-RESPONSE RELATIONSHIPS; GAUSS FUNCTION; IONIZATION CHAMBERS; KERNELS; PHOTON BEAMS; RADIATION DETECTORS; RESPONSE FUNCTIONS; SECONDARY EMISSION; SPATIAL RESOLUTION
- Descriptors DEC
- BEAMS; EMISSION; FUNCTIONS; MEASURING INSTRUMENTS; RADIATION DETECTORS; RADIATION DOSE DISTRIBUTIONS; RESOLUTION; SPATIAL DOSE DISTRIBUTIONS