Published 1989 | Version v1
Book

Evaluation of corrosion products in a pressurised water reactor during shutdown

  • 1. CEA Centre d'Etudes Nucleaires de Cadarache, 13 - Saint-Paul-lez-Durance (France)
  • 2. Electricite de France, Villeurbanne (France)

Description

During cooling, accompanied by injection of boric acid, the pH of the primary fluid becomes acid and creates a significant increase in the activity of corrosion products in solution. The change in the primary medium from reducing to oxidizing conditions produces a significant increase in cobalt isotope activity. The separate effects of cooling and oxygenation are quantified and presented in detail. The consequences of the different shutdown phases on primary circuit contamination are discussed. (author)

Additional details

Publishing Information

Publisher
British Nuclear Energy Society.
Imprint Place
London (UK)
ISBN
0 7277 1547 X (set of 2 vols.)
Imprint Title
Water chemistry of nuclear reactor systems 5. V. 2
Imprint Pagination
194 p.
Journal Page Range
p. 35-39.

Conference

Title
5. International conference on water chemistry of nuclear reactor systems.
Dates
23-27 Oct 1989.
Place
Bournemouth (UK).

Optional Information

Notes
Imprint:Proceedings published in 2 vols.