Published November 1989 | Version v1
Report

High resolution magnetic spectrograph 'Grand Raiden'

  • 1. Osaka Univ., Ibaraki (Japan). Research Center for Nuclear Physics

Description

In the report of the last 1988, the basic design of a new high resolution (p/Δp = 37750) magnetic spectrograph of the type QSQDMD (+D), named 'Grand Raiden', was presented. Here, we show results of more detailed ray-tracing calculations; the focal line property, the image aberration, and the compensation of the kinematic broadening by multipole fields. The final design of the new DSR (dipole for spin rotation) for the measurement of in-plane spin observables are also reported. (author)

Part of:
Proceedings of the workshop on 'cyclotron cascade project'

Additional details

Publishing Information

Imprint Title
Proceedings of the workshop on 'cyclotron cascade project'
Imprint Pagination
242 p.
Journal Page Range
p. 214-218.
Report number
RCNP-P--107

Conference

Title
Workshop on 'cyclotron cascade project'.
Dates
13-15 Mar 1989.
Place
Ibaraki, Osaka (Japan).

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
21064791
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ENERGY RESOLUTION; LINEAR MOMENTUM; MAGNETIC SPECTROMETERS; MAGNETS; PERFORMANCE; SPECIFICATIONS
Descriptors DEC
EQUIPMENT; MEASURING INSTRUMENTS; RESOLUTION; SPECTROMETERS

Optional Information