Published March 1981 | Version v1
Journal article

System for triggering and synchronization for the installation with a streamer chamber

Description

Triggering and synchronization system for pulse voltage helium streamer chamber and electron automatics of the system, photographing the device having such chamber is described. The triggering and synchronization system includes a unit for shaping of triggering and synchronization pulses as well as a time unit. Time diagram of the system operation and circuits of unit for shaping of triggering and synchronization pulses as well as time unit circuits are presented. Shaping path of triggering pulses is synchronized with current pulse of a linear electron accelerator operating with 50 pulse/s frequency and 1 μs pulse duration. System sensitivity at the input of output pulse shaping path is 0.2 V, input resistance - 50 Ohm, output signal duration - 100 ns. Operation cycle (blocking duration) of the system amounts to 0.1; 0.2; 0.4; 0.5; 1; 2; 4; 6; 8; 10 s. Maximum amplitude of output generator pulse is 390 kV. It is concluded that the system is reliable and possesses great capacity for work

Additional details

Additional titles

Original title (Russian)
Система запуска и синхронизации установки со стримерной камерой

Publishing Information

Journal Title
Prib. Tekh. Ehksp.
Journal Issue
no.2
Series
Prib. Tekh. Ehksp.
ISSN
0032-8162

Optional Information

Notes
For English translation see the journal Instruments and Experimental Techniques (USA).