Published April 2006 | Version v1
Journal article

A computer program for single-injection tracer clearance from one, two, or many blood samples

  • 1. University of Alabama, Hospital Birmingham, Alabama (United States)

Description

A computer program based on a Bayesian statistical model has been developed for calculating tracer clearance from any number of plasma samples drawn at arbitrary time intervals. Bayesian prior parameters were calculated from clinical data for Tc99m-MAG3, Tc99m-EC, I131-OIH, Tc99m-DTPA, and Yb169-DTPA and then used to calculate clearance from prospective data. Clearance estimates using only one or two plasma samples were found to closely approximate the results of using multiple samples. When only one or a few samples are available, the program supplements the observed data by a Bayesian prior probability distribution (based on prior clinical measurements) to achieve agreement with multi sample clearance. When many points are available, the observed data overwhelm the prior probability, and results approach those of conventional curve fitting but with less sensitivity to bad data points and less risk of fitting failure (au)

Additional details

Publishing Information

Journal Title
ALASBIMN Journal
Journal Volume
8
Journal Issue
32
Journal Page Range
[8 p.]
ISSN
0717-4055

Optional Information

Notes
17 refs., 2 fig., 4 tab