Published 1992 | Version v1
Book

Superconductive junctions for x-ray spectroscopy

  • 1. Space Research Organization of the Netherlands, Utrecht (Netherlands). Lab. for Space Research
  • 2. Twente Univ. (Netherlands). Low Temperature Group

Description

Biasing of SIS-junctions for the purpose of high energy resolution x-ray detection is complicated by the presence of a DC Josephson current and AC Josephson current resonances, so that a large magnetic field is normally used for the suppression of these Josephson features. A transimpedance amplifier is proposed for biasing and signal amplification at low magnetic field. X-ray spectroscopy detectors for astronomy require a high detection efficiency in the 0.5-10 keV energy band and a reasonable (∼1 cm2) detector area. Calculations on absorber-junctions combinations which might meet these requirements are presented. (author) 9 refs.; 10 figs

Part of:
Low temperature detectors for neutrinos and dark matter IV

Additional details

Publishing Information

Publisher
Editions Frontieres.
Imprint Place
Paris (France)
ISBN
2-86332-113-7
Imprint Title
Low temperature detectors for neutrinos and dark matter IV
Imprint Pagination
[528 p.].
Journal Page Range
p. 265-273.

Conference

Title
4. International workshop on low temperature detectors for neutrinos and dark matter.
Dates
4-7 Sep 1991.
Place
Oxford (United Kingdom).

Optional Information