Fast super-resolution ultrasound microvessel imaging using spatiotemporal data with deep fully convolutional neural network
Creators
- 1. Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN (United States)
- 2. Department of Ultrasound, Guangdong Key Laboratory of Liver Disease Research, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong (China)
- 3. Department of Urology, Mayo Clinic College of Medicine and Science, Rochester, MN (United States)
Description
Ultrasound localization microscopy (ULM) has been proposed to image microvasculature beyond the ultrasound diffraction limit. Although ULM can attain microvascular images with a sub-diffraction resolution, long data acquisition time and processing time are the critical limitations. Deep learning-based ULM (deep-ULM) has been proposed to mitigate these limitations. However, microbubble (MB) localization used in deep-ULMs is currently based on spatial information without the use of temporal information. The highly spatiotemporally coherent MB signals provide a strong feature that can be used to differentiate MB signals from background artifacts. In this study, a deep neural network was employed and trained with spatiotemporal ultrasound datasets to better identify the MB signals by leveraging both the spatial and temporal information of the MB signals. Training, validation and testing datasets were acquired from MB suspension to mimic the realistic intensity-varying and moving MB signals. The performance of the proposed network was first demonstrated in the chicken embryo chorioallantoic membrane dataset with an optical microscopic image as the reference standard. Substantial improvement in spatial resolution was shown for the reconstructed super-resolved images compared with power Doppler images. The full-width-half-maximum (FWHM) of a microvessel was improved from 133 μm to 35 μm, which is smaller than the ultrasound wavelength (73 μm). The proposed method was further tested in an in vivo human liver data. Results showed the reconstructed super-resolved images could resolve a microvessel of nearly 170 μm (FWHM). Adjacent microvessels with a distance of 670 μm, which cannot be resolved with power Doppler imaging, can be well-separated with the proposed method. Improved contrast ratios using the proposed method were shown compared with that of the conventional deep-ULM method. Additionally, the processing time to reconstruct a high-resolution ultrasound frame with an image size of 1024 × 512 pixels was around 16 ms, comparable to state-of-the-art deep-ULMs. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1361-6560/abeb31Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 66
- Journal Issue
- 7
- Journal Page Range
- [15 p.]
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 53063612
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- DATA ACQUISITION; FETAL MEMBRANES; LIVER; MACHINE LEARNING; SPATIAL RESOLUTION
- Descriptors DEC
- ALGORITHMS; ARTIFICIAL INTELLIGENCE; BODY; DATA PROCESSING; DIGESTIVE SYSTEM; GLANDS; LEARNING; MATHEMATICAL LOGIC; MEMBRANES; ORGANS; PROCESSING; RESOLUTION