Published September 2005 | Version v1
Journal article

Heat balance test analysis of determined reactor core power for Ling'ao Nuclear Power Station

Creators

  • 1. Daya Bay Nuclear Power Operations and Management Co., Ltd., Shenzhen (China). Technical Dept.

Description

To guarantee the reactor core power correctly measured by the PRN system during reactor operation, domestic KME (test instrumentation system) which measure reactor core power by heat balance is used in Ling'ao Nuclear Power Station. The theory of the heat balance, differences of measuring method from Daya Bay NPS, technology improve and problems are mainly described. (author)

Additional details

Publishing Information

Journal Title
Chinese Journal of Nuclear Science and Engineering
Journal Volume
25
Journal Issue
3
Journal Page Range
p. 271-278
ISSN
0258-0918

Optional Information

Notes
3 figs., 1 tab.