Image quality of DWI at breast MRI depends on the amount of fibroglandular tissue. Implications for unenhanced screening
Creators
- 1. Department of Epidemiology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands)
- 2. Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands)
- 3. Department of Radiology, Utrecht University, University Medical Center Utrecht, Utrecht (Netherlands)
- 4. Department of Radiology, Medisch Spectrum Twente, Enschede (Netherlands)
- 5. Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna (Austria)
- 6. Institute for Diagnostic Accuracy, Groningen (Netherlands)
Description
To compare image quality of diffusion-weighted imaging (DWI) and contrast-enhanced breast MRI (DCE-T1) stratified by the amount of fibroglandular tissue (FGT) as a measure of breast density. Retrospective, multi-reader, bicentric visual grading analysis study on breast density (A-D) and overall image and fat suppression quality of DWI and DCE-T1, scored on a standard 5-point Likert scale. Cross tabulations and visual grading characteristic (VGC) curves were calculated for fatty breasts (A/B) versus dense breasts (C/D). Image quality of DWI was higher in the case of increased breast density, with good scores (score 3-5) in 85.9% (D) and 88.4% (C), compared to 61.6% (B) and 53.5% (A). Overall image quality of DWI was in favor of dense breasts (C/D), with an area under the VGC curve of 0.659 (p < 0.001). Quality of DWI and DCE-T1 fat suppression increased with higher breast density, with good scores (score 3-5) for 86.9% and 45.7% of density D, and 90.2% and 42.9% of density C cases, compared to 76.0% and 33.6% for density B and 54.7% and 29.6% for density A (DWI and DCE-T1 respectively). Dense breasts show excellent fat suppression and substantially higher image quality in DWI images compared with non-dense breasts. These results support the setup of studies exploring DWI-based MR imaging without IV contrast for additional screening of women with dense breasts. Our findings demonstrate that image quality of DWI is robust in women with an increased amount of fibroglandular tissue, technically supporting the feasibility of exploring applications such as screening of women with mammographically dense breasts.
Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 34
- Journal Issue
- 7
- Journal Page Range
- p. 4730-4737
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 55072596
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CARCINOMAS; COMPARATIVE EVALUATIONS; CONTRAST MEDIA; DATA COMPILATION; DENSITY; DIFFUSION; FATS; FEASIBILITY STUDIES; GADOLINIUM COMPLEXES; IMAGE PROCESSING; MAMMARY GLANDS; NMR IMAGING; RELAXATION TIME; SCREENING; WEIGHTING FUNCTIONS
- Descriptors DEC
- BODY; COMPLEXES; DATA; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; FUNCTIONS; GLANDS; INFORMATION; NEOPLASMS; ORGANS; PHYSICAL PROPERTIES; PROCESSING; RARE EARTH COMPLEXES