Conventional roentgenograms of 25 patients who underwent combined aortic and mitral valve replacement were evaluated and correlated with pre- and postoperative functional and haemodynamic parameters. The roentgenograms were obtained 6 months before and up to 24 months after valve replacement. A reduction in heart size could be seen in nearly all patients. This was independent of clinical and haemodynamic results. An increase in heart size always suggests severe haemodynamic worsening, especially a paravalvular leakage. The most valuable X-ray sign is the degree of pulmonary congestion, which is well correlated with the cardiac index. (orig.)
Abstract (German)
Bei 25 Patienten mit Aorten-Mitralklappenersatz wurden die Roentgenaufnahmen zum Zeitpunkt 6 Monate praeoperativ und bis zu 24 Monaten postoperativ ausgewertet und in Beziehung zu prae- und postoperativ bestimmten klinischen und haemodynamischen Parametern gesetzt. Eine Rueckbildung der pulmonalen Stauungszeichen spricht fuer eine Zunahme des Cardiac-Index. Unabhaengig vom klinischen oder haemodynamischen Operationsergebnis nimmt die Herzgroesse innerhalb der ersten 6 postoperativen Monate im Mittel um etwa 20% ab. Eine Zunahme der Herzgroesse im postoperativen Verlauf legt den Verdacht auf eine Klappenfehlfunktion oder anderweitige haemodynamische Stoerungen nahe. (orig.)Additional details
Additional titles
- Original title (German)
- Diagnostische Aussagekraft der Nativroentgendiagnostik fuer die Beurteilung der Haemodynamik nach kombiniertem Aortenmitralklappenersatz
Publishing Information
- Journal Title
- Roentgen Bl.
- Journal Volume
- 35
- Journal Issue
- 11
- Series
- CODEN: ROBLA.;Roentgen Bl.
- Journal Page Range
- 398-402
- ISSN
- 0300-8592
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 14755240
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CARDIOVASCULAR DISEASES; CHEST; CORRELATIONS; DIAGNOSIS; FLOW RATE; HEART; IMAGE PROCESSING; IMAGES; PATIENTS; PROSTHESES; SIZE; SURGERY
- Descriptors DEC
- BODY; BODY AREAS; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; MEDICAL SUPPLIES; MEDICINE; ORGANS