Published 1988 | Version v1
Journal article

An improved method for the determination of the neutron fluence in fission power reactors based on the 93Nb(n,n')93mNb reaction

  • 1. Kossuth Lajos Tudomanyegyetem, Debrecen (Hungary)
  • 2. Nuclear Power Station (PAV), Paks (Hungary)

Description

The X-ray fluorescence method was introduced to measure the weight of an Nb monitor used for the neutron fluence measurement via the 93Nb(n,n')93mNb reaction in a fission reactor. Results were compared with those obtained by γ-spectrometry based on the 93Nb(n,γ)94Nb reaction. For comparison, the specific activities of 93mNb measured in two different laboratories are also given. (author)

Additional details

Publishing Information

Journal Title
Annals of Nuclear Energy
Journal Volume
15
Journal Issue
10-11
Series
Ann. Nucl. Energy.
Journal Page Range
523-525
ISSN
0306-4549
CODEN
ANEND