An 125I quantity indication system is introduced. 125I is a radioisotope commonly used in nuclear medicine departments. This radioisotope emits y photons with energy of about 30 keV, with half-life of 60 days. Low energy and long life-time enable to produce 125I by large quantities due to the relatively easy transportation possibilities, enabling radiation safety and long distribution distance. A unique customized quality control monitoring system was developed by Rotem Industries for a pharmaceutical company. The quality control check is performed on each 125I vial by measuring its activity with the micro-controller based radiation meter that also determines whether to accept or reject a vial. The meter stores the radioactivity results for documentation and for average processing, in order to indicate the activity filling trend. This trend can be used for a closed feedback loop in order to control and improve the vials filling during production

Files

31049581.pdf

Files (128.7 kB)

Name Size Download all
md5:cd6276983672190cf9099e5ebae14188
128.7 kB Preview Download
Part of:
Final program and book of abstracts

Additional details

Publishing Information

Imprint Title
Final program and book of abstracts
Imprint Pagination
287 p.
Journal Page Range
p. 251-254
Report number
INIS-IL--005

Conference

Title
20. conference of the Nuclear Societies in Israel
Dates
20-21 Dec 1999
Place
Dead Sea (Israel)

Optional Information