Published January 1981 | Version v1
Journal article

Advanced technologies of cardiovascular nuclear medicine and their evaluation in clinical practice

  • 1. Tokyo Metropolitan Geriatric Medical Center (Japan)

Description

Currently available advanced methods of cardiovascular nuclear medicine for the diagnosis of ischemic heart disease were studied. The methods included the multigate method by a large capacity gamma camera-computer (128 KW memory with multilayer disc) system which made it possible to acquire the data of either the first pass study or the equilibrium study in ''image mode''. Analyzed data were displayed on a color CRT using our moving image system (MIS) and dynamic image thus obtained serve to help for the high sensitive observation of the regional wall motion as well as the global function of the ventricles. Myocardial tomography by a 7 pinhole collimator designed by us was also reported. The myocardial tomogram obtained was proven to show more sensitivity than two dimensional myocardial scan by the conventional collimator to detect smaller lesion and the lesions at the inferior or posterior wall of the left ventricle. The cardiovascular nuclear medicine with recent advanced technologies was thought to be sensitive and useful method for the diagnosis of the ventricular performance and the myocardial ischemia. (author)

Additional details

Publishing Information

Journal Title
Nippon Junkankigaku-Shi
Journal Volume
45
Journal Issue
1
Series
Nippon Junkankigaku-Shi.
Journal Page Range
71-78
ISSN
0047-1828

Conference

Title
Symposium on the present status of cardiovascular nuclear medicine.
Dates
28 Mar 1980.
Place
Nagoya, Japan.