Published July 1985 | Version v1
Journal article

Correlation of treatment volume with milligram-hours for intracavitary applications for carcinoma of the cervix

  • 1. Medical College of Wisconsin, Milwaukee

Description

Following the recommendations of the European Curietherapy Group, the three-dimensional dose distribution corresponding to various milligram-hour volumes has been analyzed according to its length, width, and height dimensions. Thus, it is possible to state the dimensions of a number of isodose surfaces for a dose prescription given in milligram-hours. Problems associated with the exact placement of the three-dimensional dose distribution in relation to the patient's anatomy are discussed

Additional details

Publishing Information

Journal Title
Int. J. Radiat. Oncol., Biol. Phys.
Journal Issue
no.7
Series
Int. J. Radiat. Oncol., Biol. Phys.
ISSN
0360-3016
CODEN
IOBPD

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
17016933
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CARCINOMAS; FEMALE GENITALS; RADIATION DOSE DISTRIBUTIONS; RADIOTHERAPY; RADIUM
Descriptors DEC
ALKALINE EARTH METALS; BODY; DISEASES; ELEMENTS; MEDICINE; METALS; NEOPLASMS; ORGANS; THERAPY