Published February 1977 | Version v1
Journal article

Evaluation of fuel performance in reactor (PWR)

Creators

  • 1. Kansai Electric Power Co., Inc., Osaka (Japan)

Description

The ratios of primary coolant concentration of 131I to 133I and 135I to 133I are expressible as one point in the area surrounded by two straight lines and two rectangular hyperbolas having a fixed common point in the rectangular coordinate system of the above two ratios. And fuel defect level, exposed tramp uranium level and primary purification rate are obtained conveniently in the above figure. Some remarks to these procedures are also presented. (auth.)

Availability note (English)

Available from DOI: https://doi.org/10.3327/jaesj.19.102

Additional details

Additional titles

Original title (Japanese)
加圧水型原子炉における燃料欠陥率の評価

Identifiers

Publishing Information

Journal Title
Nippon Genshiryoku Gakkai-Shi
Journal Volume
19
Journal Issue
2
Journal Page Range
p. 102-106
ISSN
0004-7120

Optional Information

Notes
3508700; This record replaces 08341014