Published January 1999 | Version v1
Book

Determination of arsenic in ground water at trace level by particle induced x-ray emission (PIXE) technique using proton beam

  • 1. Analytical Chemistry Div., Variable Energy Cyclotron Centre, Bhabha Atomic Research Centre, Calcutta (India)
  • 2. Radiochemistry Div., Variable Energy Cyclotron Centre, Bhabha Atomic Research Centre, Calcutta (India)
  • 3. Analytical Chemistry Div., Bhabha Atomic Research Centre, Mumbai (India)
  • 4. Institute of Physics, Bhubaneswar (India)

Description

Arsenic has been reported to be present at trace levels in ground water in different parts of West Bengal and Bangladesh. Since As is a toxic element, it is important to determine the level of As present in the drinking water. PIXE technique has been applied to determine As in ground water collected from different sources. (author)

Part of:
Proceedings of nuclear and radiochemistry symposium

Additional details

Publishing Information

Publisher
Bhabha Atomic Research Centre
Imprint Place
Mumbai (India)
Imprint Title
Proceedings of nuclear and radiochemistry symposium
Imprint Pagination
466 p.
Journal Page Range
p. 331-332

Conference

Title
nuclear and radiochemistry symposium
Acronym
NUCAR 99
Dates
19-22 Jan 1999
Place
Mumbai (India)

Optional Information

Notes
3 refs., 1 tab.