Published February 6, 1995 | Version v1
Journal article

Performance of the Huygens detectors at intermediate energies

  • 1. Universiteit Utrecht/NIKHEF, Dept. of subatomic physics, P.O. Box 80.000, 3508 TA Utrecht (Netherlands)
  • 2. GANIL, BP 5027, 14021 Caen Cedex (France)

Description

An experiment with the Huygens detectors has been performed at GANIL (France). These Huygens detectors comprise two detectors: a central detector, which consists of a time projection chamber (TPC) surrounded by a plastic scintillator barrel, and a CsI(Tl) wall in the backward region. In addition, in the forward hemisphere a plastic hodoscope ('MUR') is used in conjunction with the forward plastics of the Huygens plastic scintillator barrel. In this paper first results will be presented. ((orig.))

Additional details

Publishing Information

Journal Title
Nuclear Physics. A
Journal Volume
583
Journal Page Range
p. 457C-460C.
ISSN
0375-9474
CODEN
NUPABL

Conference

Title
5. international conference on nucleus nucleus collisions.
Dates
30 May - 4 Jun 1994.
Place
Taormina (Italy).