Published 2009 | Version v1
Report Open

The calculation and construction of the Nuclotron-M radiation shielding for the operative design

Description

An extremely simple and universal method has been suggested for calculation of the shielding of any configuration (except the traps) over the given losses of accelerated particles. The method is comfortable when operatively solving the problems of shielding and predicting the radiation situation. The error of the shielding thickness calculations is less than 10%. The neutrons escaped from the Nuclotron shielding and multiscattered in air and ground will form the radiation situation around the modernized Nuclotron-M. A variant of the Nuclotron shielding design using the synchrophasotron magnet elements is proposed

Availability note (English)

Also available online: http://www1.jinr.ru/Preprints/2009/180(P16-2009-180).pdf

Files

42083617.pdf

Files (2.5 MB)

Name Size Download all
md5:d8ce54bb817b1da0d335cb7f5ac48729
2.5 MB Preview Download

System files (20.5 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Расчет и конструирование радиационной защиты нуклотрона-М на стадии технического задания на проектирование

Publishing Information

Imprint Pagination
10 p.
Report number
JINR-R--16-2009-180

INIS

Country of Publication
Joint Institute for Nuclear Research (JINR)
Country of Input or Organization
Joint Institute for Nuclear Research (JINR)
INIS RN
42083617
Subject category
S07: ISOTOPES AND RADIATION SOURCES; S43: PARTICLE ACCELERATORS;
Descriptors DEI
BIOLOGICAL SHIELDING; ERRORS; JINR SYNCHROTRON; PROTON BEAMS; RADIATION DOSES; SPATIAL DISTRIBUTION; THICKNESS
Descriptors DEC
ACCELERATORS; BEAMS; CYCLIC ACCELERATORS; DIMENSIONS; DISTRIBUTION; DOSES; NUCLEON BEAMS; PARTICLE BEAMS; SHIELDING; SYNCHROTRONS

Optional Information

Notes
4 refs., 4 figs., 2 tabs. Submitted to the organizing committee of 22. all-russian conference on charged particle accelerators (RUPAC-2010, Protvino, Oct 2010)